SM50-H
|
|
|
| Electrical
Parameters1
|
|
12V |
| Maximum
power rating, Pmax |
[Watts] |
50 |
| Minimum
power rating, Pmin |
[Watts] |
45 |
| Rated
current, Imp |
[Amps] |
3.15 |
| Rated
voltage, Vmp |
[Volts] |
15.9 |
| Short
circuit current, Isc |
[Amps] |
3.35 |
| Open
circuit voltage, Voc |
[Volts] |
19.8 |
| Thermal
Parameters |
|
|
| Nominal
operating cell temperature2 |
[°C] |
45 |
| Change
of Isc with temperature |
|
+01.2mA/°C
(+0.04%/K) |
| Change
of Voc with temperature |
|
-0.071
Volts/°C
(-0.34%/K) |
| Qualification
Test Parameters3 |
|
|
| Temperature
cycling range |
[°C] |
-40
to +85 |
| Humidity,
freeze, damp heat condition |
[%
RH] |
85 |
| Maximum
system voltage |
[Volts] |
1000
per ISPRA (EC)
600 per UL1703 |
| Wind
loading or surface pressure |
[N/m²]
(lb/sqft) |
[2400]
(50) |
| Maximum
distortion4 |
[degrees] |
1.2 |
|
Hailstone
impact withstand (diameter
@ velocity)
|
[mm
@ m/s]
(in @ MPH) |
25
@ 23
(1.0 @ 52) |
| Physical
Parameters |
|
|
| Number
of cells in series |
|
33 |
| Length |
[mm]
(in) |
1219
(48.0) |
| Width |
[mm]
(in) |
329
(13.0) |
| Depth |
[mm]
(in) |
34
(1.3) |
| Weight |
[kg]
(lb) |
5.2
(11.5) |
| Warranty5 |
|
|
| Power
>or= 90% of minimum power rating above |
[Years] |
10 |
| Power
>or= 80% of minimum power |
[Years] |
25 |